Gas Front Igniters
Reference: 25-T-PET-2010 6/7/2010, Location: Middle East
Category: Transmitters, Pressure
Scope of Work
1- # 6 CE. gas front igniter with ionic monitoring system The igniter is complete set Vender: dw # D- 902 0133 Also the vendor will supply the control Cabinet for C- E- IFM Gas igniter complete with the IFM Card and H.T Transformer
2- # 25 Differential Pressure Transmitters Power supply: 24 VDC Span adjustment: (5 500) Kpa Output signal: (4 20) mA Minimum working pressure: 10 bar Process connection: 1/2" FNPT Housing Explosion Proof Element: 316 S.S wetted part Over range: 27 560 Kpa Max . temp . for capsule : 406 Cú
3- # 20 Pressure Transmitters Power supply: 24 VDC Span adjustment: (5 5000) Kpa Output signal: (4 20) mA Over range: 27 560 Kpa Max. temp . for cap sulea : 406 Cú Housing Explosion proof Element: 316 S.S wetted parts Process connection: 1/2" FNPT
4- # 4 Water columns for Boiler dram 4 Complete water columns with four (4) probe electric Probe for model 3 water columns alarm liquid Type flange (6" 600) Rating 52.7 bar Water columns length (1730) mm
5- Spares for the water columns
6- # 12 Control system Type: 25 SU 5 N Model: 4011 C In fir eye Burner control system
7- # 4 G.V.V (Vent valve) Maxon "STO" vent valve Maxon Corporation, munie in 47302 Designation: 2" STO ASO Serial No: 92 A212987 Max. Inlet pressure: 70 PSIG Solenoid: 120 / 60 Closing: 264 VA Holding: 24 VA Closing Time: 2.5 SEC Trim: 2.2 For use with air natural gas LP GAS, 1 & 2 fuel oils Ambient temp. Range: Min 20 F max. 140 F (AC) Max. Fluid Temp 140 F (AC) Enclosures NEMA: 1, 2, 3, 3R, 4 & 12 CSA2, 4 & 5 PAT No 3.508.446 OR 3-082 627 OR 3.685. 790 Manufacture: Maxon
8- # 6 Maxon - Shut Off Valve Maxon Corporation munie IN 47302 Designation: 6" FLD Repl Serial number: 92 A212985 Max inlet pressure: 50 PSI Solenoid: 120 / 60 Motor: 120 / 60 Opening: 434 VA Holding: 14 VA Opening Time: 12sec For use with Air natural Gas LP Gas Ambient Temp Range: min 20F max 140 F (AC)
9- # 6 Control valve FV (8104) Complete valve with positioner Model No: 35 35202 Serial No: J 13497 2 2 Size: 6" Port: CV 500 Supply: 35 bar Range: (20 100) Kpa Action: Air to open Mat. (Plug): 316 HF (Seat): TFFL Vendor: Mosoneilan Many Fuctures: U.S.A (Mosoneilan)
10- Spares for that valve # 20 Pneumatic Positioner Model No: 4612 Series No: 4600
11- # 6 Diaphragm for the valve Serial No: 35202
12- # 6 Control valve FV (8101) Model No: 37 40 214 6 A3 Serial No: J 13 497 1 3 Size: 4" Port: CV 95 Supply: 35 bar Range: (20 100) Kpa Action: Air to close Vender: Mosoneilan Many fuctures: U.S.A (Mosoneilan) Complete with Positioner
13- # 6 Primary air damper control drive Hagan model: PP 405 T 212 Manufacture: Bailey Serial No: 120 4 × 5 Inch Torque Type Power Positioner Operating air: 45 PSI to 120 PSI Supply pressure Recommended air: 100 PSI Supply pressure Complete with Positioner
|
Related Prooducts: Transmitters, Pressure
Analyzers, Gas
Calibration Equipment
Calibrators, Electronic, Pneumatic
Concentration
Conductivity Meters
Density
Detector, Gas
Dissolved Oxygen meters
Drilling Instruments
Float Switch
Gas meters
General
Indicators and Recorders
Leak Locators
Level meters
Liquid Measurement
Load cells
Monitoring & Control
Mud Control
Mud Logging
pH and REDOX
Pressure gauges/ Transmitters
Radiation Detection
SCADA Systems
Temperature gauges/ Transmitters
Thermocouples
Thermowells
Transducers
Transmitters
Transmitters, Pressure
Turbidity Meters
Viscosity
Weather Station
Weighing Equipment
Related Tenders:
Analyzers, Gas
Calibration Equipment
Calibrators, Electronic, Pneumatic
Conductivity Meters
Density
Detector, Gas
Dissolved Oxygen meters
Drilling Instruments
Gas meters
General
Indicators and Recorders
Leak Locators
Level meters
Liquid Measurement
Monitoring & Control
Mud Logging
Pressure gauges/ Transmitters
SCADA Systems
Temperature gauges/ Transmitters
Thermocouples
Thermowells
Transmitters
Transmitters, Pressure
Viscosity
Weather Station
|
|
|
|