Fuel Consumption Flow Meters
Reference: N.F 4501/2010 10/19/2010, Location: Middle East
Category: Gas meters
Scope of Work
1- Supply of # 4 electronic flow meters to measure the consumption as the following specifications: Product: (HN & LN) Pipe size: 1.5" vertical installation Flow direction towards up F.R.R.: (0.1 to 1.5) m³/hr Op.Temp: (30 to 85) Cº Op. pressure: (9 – 10) bar Differential pressure: 0.5 bar Sp. Gr.: (0.65 to 0.75) Used for units (1, 2, 3) Fueling (liquid phase) to the furnaces with strainer and air release.
2- Supply of # 4 electronic flow meters to measure the consumption as the following specifications: Product: Off Gas mixture of (C1, C2, C3, C4, H2, H2s) Pipe size: 4" horizontal installation F.R.R.: (100 to 500) Nm³/hr Op.Temp: (30 to 65) Cº Op. pressure: (0.1 to 2.5) bar Differential pressure: 0.05 bar Density: 3.4 Kg/m³ Used for units (1, 2, 3) Fuel (gas phase) to the flair
3- Supply of # 4 electronic flow meters to measure the consumption as the following specifications: Product: Off Gas mixture of (C1, C2, C3, C4, H2, H2S) Pipe size: 4" horizontal installation F.R.R.: (30 to 350) Nm³/hr Op.Temp: (30 to 65) Cº Op. pressure: (0.1 to 2.5) bar Differential pressure: 0.05 bar Density: 3.4 Kg/m³ Used for units (1, 2, 3) Fuel (gas phase) to the furnaces These flow meters should be blind head type (equipped with a separate remote Display) mounted on the wall
4- Supply of # 3 electronic flow meters to measure the consumption as the following specifications: Product: Gas Oil Pipe size: 1.5 "horizontal installation F.R.R.: (2 to 20) m³/hr Op.Temp: (10 to 65) Cº Op. pressure: (2 to 3) bar Differential pressure: 0.3 bar For units (1, 3) Fuel (liquid phase to the Boiler & Generator. Water & Sediment V%: 0.05 ASH Max% 0.01 weight These flow meters should be blind head type (equipped with a separate display) mounted on the wall (remote) with strainer and air release
5- Supply of # 1 electronic flow meters to measure the consumption as the following specifications: Product: Gas Oil Pipe size: 1.5" horizontal installation F.R.R.: (1 to 10) m³/hr Op.Temp: (10 to 65) Cº Water & Sediment V%: 0.05 ASH Max% 0.01 weight Op. pressure: (2 to 3) bar Differential pressure: 0.3 bar For unit (2) Fuel (liquid phase) to the Boiler These flow meters should be blind head type (equipped with a separate remote display) mounted on the wall with strainer and air release
6- Supply of # 2 electronic flow meters to measure the consumption as the following specifications: Product: Gas Oil F.R.R.: (1 to 10) m³/hr Op.Temp: (10 to 65) Cº Water & Sediment V%: 0.05 ASH Max% 0.01 weight p. Pressure: (2 to 3) bar Differential pressure: 0.3 bar For unit (2) Fuel (liquid) to the Generator with strainer and air release
|
Related Prooducts: Gas meters
Analyzers, Gas
Calibration Equipment
Calibrators, Electronic, Pneumatic
Concentration
Conductivity Meters
Density
Detector, Gas
Dissolved Oxygen meters
Drilling Instruments
Float Switch
Gas meters
General
Indicators and Recorders
Leak Locators
Level meters
Liquid Measurement
Load cells
Monitoring & Control
Mud Control
Mud Logging
pH and REDOX
Pressure gauges/ Transmitters
Radiation Detection
SCADA Systems
Temperature gauges/ Transmitters
Thermocouples
Thermowells
Transducers
Transmitters
Transmitters, Pressure
Turbidity Meters
Viscosity
Weather Station
Weighing Equipment
Related Tenders:
Analyzers, Gas
Calibration Equipment
Calibrators, Electronic, Pneumatic
Conductivity Meters
Density
Detector, Gas
Dissolved Oxygen meters
Drilling Instruments
Gas meters
General
Indicators and Recorders
Leak Locators
Level meters
Liquid Measurement
Monitoring & Control
Mud Logging
Pressure gauges/ Transmitters
SCADA Systems
Temperature gauges/ Transmitters
Thermocouples
Thermowells
Transmitters
Transmitters, Pressure
Viscosity
Weather Station
|
|
|
|