Electrical Vertical Pumps in Zubair Degassing Station
Reference: BID7645 4/8/2009, Location: Middle East
Category: Vertical Centrifugal Pump
Ref. No.: 96-08-3825
Issue Date: 08/04/2009
Bid Closing Date: 01/05/2009
Fee: 600 USD
Bid Bond: 1% From the total value of tender price
Offer Validity: 120 days from the Bid Closing Date
Bond Validity: 90 days from the Bid Closing Date
Scope of Work:
South Oil Company requires two electrical vertical pumps in Zubair degassing station.
The crude oil will be pumped from flow tanks to (Zubair1 station) at 1 km distance through 24" conveyer line.
One complete motor panel controller including all options (with auto-running facilities). Interconnecting pipes at least 50 m, fitting, valves, strainers, power & control cables, and all accessories as requirements.
- Electrical Vertical Pump specification: (ACC. to API 610 latest addition)
Casing: carbon steel
Impeller: s.steel
Shat: s. steel
Case wearing ring: s.steel
Shaft sleeve: s. steel
Suction nozzle: ANSI 300# RF
Discharge nozzle: ANSI 300# RF
Type of filter: self cleaning
Type of cooling: internal cooling & multi cyclone separator.
Type of seal: single mechanical seal & internal cooling by crud oil.
Pump efficiency: as high as possible.
- Electric motor specification:
3 PH squirrel cage induction motor, explosion protection design, flame enclosure EEX DE IIB T4 according to EN 50018, IEC 60079-1 & EN 50019, IEC 60079-7 and with following specification:
Rated voltage: 11 kv
Rated power: 10% greater than mechanical absorbed power.
Rated frequency: 50 hz
Insulation class: f with temp. rise class B
Duty: 1 s
Degree of protection: IP 55
Method of starting: direct
Design temp.: suitable to use in amb. temp. (0 °c-55 °c)
Power factor: not less than (0.89) at full load
Complete with space heater 2x3 pt 100 (for winding), 2x3 PT 100 (for bearing)-
- # 2 Set out door use local control panel, stainless steel enclosure, IP 55 suitable to use at zone 2 classified area and have the following features:
Local / remote-switch, Signal lamp power on, Signal lamp common alarm, Ammeter with selector switch, Operation counter, Push buttons for open /close motor operate, Signal lamps for open / close motor operated gate valves, emergency push button.
- # 2 Set complete instrumention packages should be included within the material of supply. The instruments should include and not limited to:
1- All local instruments including protection sensor and gauges.
2- Local control and operating panel for each pump separately.
3- Common control remote panel with minic to be installed inside the control room to control and operate each pump individually.
4- All required control cables to be connected between local site equipments and remote control panel inside the control room not less than 350 mtr.
- # 2 Cabling system:
All cables requirments (mv, lv) to be included taking in to considration the distance between the electrical source and pump area is 350 mtr.
- # 2 set two years recommended spare parts from items (1.2 & 1.3), an itemized & priced in commercial offer.
Origin and manufacturing shall be from (West European, USA, Japan).
|