Supply of Instrument
Reference: BID97101030 3/15/2011, Location: Middle East
Category: Instruments
Scope of Work
1. Total organic carbon analyzer:
# 1 TOC-VCSH total organic carbon analyzer. High-sensitivity modelCombustion catalytic oxidation/NDIR method, Standalone, Basic unit with Built-in operation keys, LCD display & printer .With auto sampler & all Accessories, with all reagents & spare part for two years
Specification:
- Measurement method: 680 degC combustion catalytic oxidation/NDIR method
- Operation method: standalone
- Measured items: (TC, IC, TOC, NPOC, POC, TN)
- Applicable samples: aqueous sample, solid, gas)
- Measurement range (mg/L): TC: 0 to 25000, IC: 0 to 30000
- Detection limit: 4??g/L
- Measuring time: TC: aprox. 3 mins IC: aprox. 3 mins
- Sample injection: automatic injection
- Sample injection volume: 10 to 2000µL variable
- IC pre-treatment: Automatic internal acidification and sparging
- Automatic dilution: dilution factor 2 to 50
- Carrier gas: High purity air
- Gas pressure: 300kPa
- Operating keys: built-in
- Display: built-in LCD
- Printer: built-in
- Power supply: AC220~240V
# 1 Auto sampler ASI-V
Specification:
- Vial types: 40 ml
- Number of vials: 68
- Vial septum: with dedicated septum
- Sample sparging: OK (if the external sparging kit is used)
# 1 TN (total nitrogen) unit TNM-1
Specification:
- Measurement method: Chemiluminescence
- Measured items: TN (Total Nitrogen)
- Measurement range: 0 to 4000mg/L
- Detection limit: 5µg/L
- Ozone source gas: Air (compressor air, or housing air) 500mL/min
- Measuring time: approx. 4 mins.
- Supplied gas: Air, pressure; 300kPa.
- Nitrogen carrier gas kit
- Sample adjustment tank
- Power requirement: 220 ~240V
# 1 Solid sample combustion unit SSM-5000A
Specification:
- Method: TC:catalytically aided combustion oxidation at 900°C. IC:Pre-acidification, oven temperature: 200°C.
- Measured item: TC, IC, TOC
- Measuring range: TC: 0.1 to 30mg carbon (1~20??g carbon in high sensitivity measurement) IC: 0.1 to 20mg carbon
- Sample amount: 1gram-aqueous content < 0.5g
- Analysis time: 5 to 6 minutes at a gas rate
- Carrier gas: 99.9% O2 at the 500mL/min. High-purity O2 Gas is required for high sensitivity measurement
- Power requirement: 220~240V 50/60Hz
Special accessories / one from each accessories
Specification:
- Carrier gas purification Kit
- Nitrogen carrier gas kit
- Gas Purifier, adsorption type
- Gas sample injection kit
- POC kit
- ASI-V magnetic stirrer & ASI-V stir bars 40 mL vials
- Suspended sample kit
- External sparge kit
- Air supply pipe set
- Small vial rack set for ASI-V
Requirements
Specification:
- CERAMIC FIBERx1
- Chart paper for TOC-VE (10pkt)
- O-ring,4D P20 ...5/PKTx1
- CO2 absorber,x2
- CO2 absorber,x2
- quartzwool,1GRx1
- Catalyst,st typex3
- TOC standard solution 10 L
# 1 Personal computer
Specification:
According to system requirements
2 - Chemical oxygen demand:
?# 1 spectrophotometer
Specification:
COD (chemical oxygen demand ) Photo meter lab 230 v AC euro and 240 V AC Including English manual Guaranty for defects on quality 1 year
# 1 Thermo reactor for (COD)
Specification:
Thermo reactor for (COD) and thermal digestion for up to 12 reaction cuvettes, with 3 reactors Temperature 5 programs, 220 -240 V AC
- 1x 12 sample (average 16 mm)
- Control accuracy: +/- 1Cº, +/- 1 digit
- 5 store programs
- Integrated safety hood
- Safety class 1 meeting DIN VDE 0700 teil1/11.90
- Timer function
- Displays when reaction temperature is reached Guaranty for defects on quality 1 year
COD cuvette test / 250 x 28 pk
Specification:
COD cuvette test Measurement range 0.0- 150 mg/L and high range 25 determination +3 bonus cuvette Cuvette round Used with photo lab s6/ 12 spectral or HACH Dr 2500 spectrophotometer
# 1 Blender
Specification:
Blender. 2-speed, 220 -240 V AC
# 1 COD Digestion Reagent vials.
Specification:
COD Digestion Reagent vials.
# 1 Magnetic stirrer and stir bar.
Specification:
Magnetic stirrer and stir bar. 220 -240 V
Reagents 10x200 ml Pk
Specification:
- COD Standard Solution low range
- Potassium Acid Phthalate, ACS 1000 g
- Mercuric Sulfate, 100 g
Accessories for 1000 test
Specification:
- With all suitable reagents for two years
- All Accessories suitable for test
3- Biological oxygen demand:
# 2 BOD IS 12 Measurement using OXI TOP is based on pressure measurement in a close system
Specification:
BOD 5 measuring for self ? checks with 12 measuring Units universal power supply 220 V AC 50HZ, and accessories Specification: Measuring of: BOD n Pressure range: 500 -1350 hpa Accuracy +/- 1% of value +/- hpa Resolution: 1 hpa (corresponds to 0.7 % of BOD n measuring range) Power supply: lithium batteries (280 MAH), 2XCR 2430 Ambient temperature: storage (25 -65 c)
# 1 Thermostat cabinets
Specification:
Thermostat cabinets: incubator cabinets for 2 BOD Oxitop system (12 standard bottle each) 230AC 50HZ
# 2 Magnetic stirrers
Specification:
Magnetic stirrer and it bar according to system requirement
Reagents For 1000 test
Specification:
All suitable reagents and agar
|
Related Prooducts: Instruments
Analyzers, Gas
Calibration Equipment
Calibrators, Electronic, Pneumatic
Concentration
Conductivity Meters
Density
Detector, Gas
Dissolved Oxygen meters
Drilling Instruments
Float Switch
Gas meters
General
Indicators and Recorders
Leak Locators
Level meters
Liquid Measurement
Load cells
Monitoring & Control
Mud Control
Mud Logging
pH and REDOX
Pressure gauges/ Transmitters
Radiation Detection
SCADA Systems
Temperature gauges/ Transmitters
Thermocouples
Thermowells
Transducers
Transmitters
Transmitters, Pressure
Turbidity Meters
Viscosity
Weather Station
Weighing Equipment
Related Tenders:
Analyzers, Gas
Calibration Equipment
Calibrators, Electronic, Pneumatic
Conductivity Meters
Density
Detector, Gas
Dissolved Oxygen meters
Drilling Instruments
Gas meters
General
Indicators and Recorders
Leak Locators
Level meters
Liquid Measurement
Monitoring & Control
Mud Logging
Pressure gauges/ Transmitters
SCADA Systems
Temperature gauges/ Transmitters
Thermocouples
Thermowells
Transmitters
Transmitters, Pressure
Viscosity
Weather Station
|
|
|
|