Instruments for Waste Water Treatment Unit
Reference: 19-2011 1/20/2012, Location: Middle East
Category: Water treatment Plant

Scope of Work
- Objective:
Supplying, installing and putting into operation instruments for waste water treatment unit( 32/8 ) installed in the field for local and direct measurement, on turn - key basis.

- The Required Instruments:
1- One conductivity instrument.
2- Two turbidity Instruments.
3- One PH instrument.
4- Two dissolved Oxygen analyzers.
5- One H2s meter.

- The Technical Specifications for Conductivity Meter:
1- Provided by digital screen and suitable key board.
2- Output: 4-20 m A.
3- Range: 0-2000 µ .s.
4- Accuracy: The best offered one.
5- Repeatability: The best offered one.
6- Easy to adjust, calibrate and maintain
7- To monitor faults massages.
8- Programmable alarm output (H-L).

- The Technical Specifications for Turbidity Meter:
1- Provided by digital screen and suitable key board
2- Output: 4-20 m A.
3- Range: 0-100 NTU.
4- Accuracy: the best offered one.
5- Repeatability: The best offered one.
6- Easy to adjust, calibrate and maintain
7- To monitor faults massages.
8- Programmable alarm output (H-L).

- The Technical Specifications of Ph Meter:
1- Provided by digital screen and suitable key board
2- Output: 4-20 m A.
3- Range: (0-14).
4- Accuracy: the best offered one .
5- Repeatability: The best offered one.
6- Easy to adjust, calibrate and maintain
7- To monitor faults massages.
8- Programmable alarm output (H-L).

- The Technical Specifications of Dissolved Oxygen Analyzer:
1- Provided by digital screen and suitable key board
2- Output: 4-20 m A.
3- Range: (0-5) PPM .
4- Accuracy: the best offered one .
5- Repeatability: The best offered one.
6- Easy to adjust, calibrate and maintain
7- To monitor faults massages.
8- Programmable alarm output (H-L).

7- The Technical Specifications of H2S Meter:
1- Provided by digital screen and suitable key board
2- Output: 4-20 m A.
3- Range: (0-200) P.PM.
4- Accuracy: the best offered one.
5- Repeatability: the best offered one.
6- Easy to adjust, calibrate and maintain
7- To monitor faults massages.
8- Programmable alarm output (H-L).





Related Prooducts: Water treatment Plant General 

Related Tenders: General 

Sale Prices of Natural Gas to Distributors Fall in May 2020