Gulf Oil and Gas
      Go to 3D Projects Premium Content Zone >>  |  Logon Oil and Gas

Supply of Vapour Pressure Tester
Reference: SDG0386P16/07 3/7/2016, Location: Asia
Category: Instruments

Scope of Work
The company bids for the supply of Qty: 01 No, vapour pressure tester.

The Technical Specifications are as follows:-

Vapour Pressure Tester:
- The instrument should be capable of measurement of vapour pressure of crude oil and other petroleum products automatically.
- The testing methodology should comply with ASTM D 5191, D6377, D6378, IP 394, 409, 481 and correlate with ASTM D 323, D4953, D5188, D5190, D5482 etc

Technical Detail s / specifications:
Available test methods Programmable method of ASTM D5188, D5191, D6377, D6378, D6897, IP394, IP409, IP481)
- Temperature range 0 to 120°C (32 to 248°F) with Peltier technology - No external cooling is required. Temperature stability 0.01°C (0.02°F)

Pressure range
0 to 1000 kPa (0 to 145 psi) and for LPG testing : 0 to 2000 kPa (0 to 290 psi)

Pressure units (selectable)
hPa, kPa, psi, mmHg, Torr, at, atm

Pressure resolution
0.1 kPa (0.014 psi)
Precision
Repeatability: r = 0.3 kPa (0.044 psi),
Reproducibility: R = 0.7 kPa (0.102 psi)

Vapor / Liquid ratio
Variable from 0.02/1 to 100/1
Single-point, multi-point and curve measurements

Sample introduction Automated via built-in piston.
Sample volume 1 ml (2.2 ml per rinsing cycle)

Measurement time 5 minutes for a standard measurement cleaning by next sample or solvent

Display
Industry proven 7" colour touch screen

Interfaces
Built-in PC with Ethernet, USB and RS232 interfaces Direct LIMS connectivity via LAN and output to printer or PC, (Optional) input by external keyboard, mouse and barcode reader

Remote control
Remote service capability via Ethernet interface

Result database
More than or equal to 1000 detailed test reports storable in internal memory

Operators
Operator names storable

Hazy mark
Results can be marked for hazy appearance

Alarm tracking
All messages are stored in the database together with the results

Automated calibration routine
10-point probe offset correction table, Calibration history tracking, substance Calibration, self-diagnostics

Power requirements
230V AC / 50 Hz
Provision for Field application: 12 V/9 A DC (vehicle battery also)

Dimensions
Weight: 8 to 10 kg (approx)
Length: 8 to 10 inch (approx)
Breadth 10 to 15 inch (approx)
Height: 10 to 12 inch (approx)



Related Prooducts: Instruments Analyzers, Gas  Calibration Equipment  Calibrators, Electronic, Pneumatic  Concentration  Conductivity Meters  Density  Detector, Gas  Dissolved Oxygen meters  Drilling Instruments  Float Switch  Gas meters  General  Indicators and Recorders  Leak Locators  Level meters  Liquid Measurement  Load cells  Monitoring & Control  Mud Control  Mud Logging  pH and REDOX  Pressure gauges/ Transmitters  Radiation Detection  SCADA Systems  Temperature gauges/ Transmitters  Thermocouples  Thermowells  Transducers  Transmitters  Transmitters, Pressure  Turbidity Meters  Viscosity  Weather Station  Weighing Equipment 

Related Tenders: Analyzers, Gas  Calibration Equipment  Calibrators, Electronic, Pneumatic  Conductivity Meters  Density  Detector, Gas  Dissolved Oxygen meters  Drilling Instruments  Gas meters  General  Indicators and Recorders  Leak Locators  Level meters  Liquid Measurement  Monitoring & Control  Mud Logging  Pressure gauges/ Transmitters  SCADA Systems  Temperature gauges/ Transmitters  Thermocouples  Thermowells  Transmitters  Transmitters, Pressure  Viscosity  Weather Station 

Euronav Announces 4th Quarter 2020 Results
Euronav Announces Final Year Results 2020
New Y Unsecured Sustainability Linked Revolving Credit Facility of EUR 80M
Euronav Orders Two Newbuild VLCCs & One Option to Add a Third
Exploration
Development
Oil & Gas Companies

Gulf Oil and Gas E-Marketplace - Premium Content

Copyright © Universal Solutions S.A.E. All rights reserved. Privacy Policy. - Contact Us