Supply of Digital Multi Gas Detector
Reference: JID1654L17 7/8/2016, Location: Asia
Category: Detector, Gas

Scope of Work
The company invites bids for the supply of Qty= 4 NO, Portable Digital Multi Gas Detector with Pump with Specifications as follows:-

* Measuring Gases: Combustible Gases (LEL), O2, CO & H2S

* Sensors:
- Smart Interchangeable Sensors
- Combustible Sensor: 0-100% LEL in 1% increment
- Oxygen: 0-25% volume in 0.1% increment
- Carbon Monoxide (CO): 0 # 500 ppm in 1 ppm increment
- Hydrogen Sulphide (H2S): 0 # 100 ppm in 0.1 ppm increment

- Response Time: Less than 60 sec
- Sensor life: Minimum 2 years
- Size: Handheld portable
- Weight: Less than 500 gms with Pump
- Operating Temperature Range: 0°C- 50°C
- Operating Humidity Range: 20%-95% non-condensing
- Display/Readout: Backlit Liquid Crystal Display (LCD), giving simultaneous display for all gas channels
- Case Material: Suitable for using in rugged conditions
- Ingress Protection: IP 65 (minimum)
- Sampling Pump: Should have an inbuilt pump with tubing which can draw sample up to minimum 35 feet
- Power Source/Run Time: Rechargeable Lithium-ion Battery Pack with minimum 8 hours life with pump
- Charging time: Less than 4 hrs.
- Alarms: Ultra-bright LEDs, Loud audible and vibrating alarm. The alarms should be user configurable.
- Keypad functions: on/off, calibration, configuration etc.
- Approvals: DGMS

* Accessories:
a) Battery Charger (Input 90-240 VAC) - 1 no. for each detector
b) Belt/pocket clip-1 no. for each detector
c) Soft Carrying Case - 3 nos.
d) Hard Carrying Case - 1 no. (The hard carrying case should be suitable for carrying detector with accessories, calibration gas cylinder, calibration kit etc.)
e) Calibration Kit - 1 no.
f) Combination Portable Calibration Gas Cylinder (LEL, O2, CO & H2S)-1 no.
i) Gas Volume: 50 Litre
ii) Pressure: 100 kg/cm2
iii) Stability: 1 year (minimum)

Note:
a) The detector should be supplied with all accessories required for calibration of detector.
b) The calibration gas cylinder should be certified by CCOE.



Related Prooducts: Detector, Gas Analyzers, Gas  Calibration Equipment  Calibrators, Electronic, Pneumatic  Concentration  Conductivity Meters  Density  Detector, Gas  Dissolved Oxygen meters  Drilling Instruments  Float Switch  Gas meters  General  Indicators and Recorders  Leak Locators  Level meters  Liquid Measurement  Load cells  Monitoring & Control  Mud Control  Mud Logging  pH and REDOX  Pressure gauges/ Transmitters  Radiation Detection  SCADA Systems  Temperature gauges/ Transmitters  Thermocouples  Thermowells  Transducers  Transmitters  Transmitters, Pressure  Turbidity Meters  Viscosity  Weather Station  Weighing Equipment 

Related Tenders: Analyzers, Gas  Calibration Equipment  Calibrators, Electronic, Pneumatic  Conductivity Meters  Density  Detector, Gas  Dissolved Oxygen meters  Drilling Instruments  Gas meters  General  Indicators and Recorders  Leak Locators  Level meters  Liquid Measurement  Monitoring & Control  Mud Logging  Pressure gauges/ Transmitters  SCADA Systems  Temperature gauges/ Transmitters  Thermocouples  Thermowells  Transmitters  Transmitters, Pressure  Viscosity  Weather Station 

Great Lakes Announces Receipt of $90.3M in Awarded Work
Just Energy Provides Update on CCAA Process
First Solar Appoints Kathryn A. Hollister to Board of Directors
dship Carriers Launches New F-500 Vessel MV Charlie
Exploration
Development
Oil & Gas Companies

Gulf Oil and Gas E-Marketplace - Premium Content

Copyright © Universal Solutions S.A.E. All rights reserved. Privacy Policy. - Contact Us