Procurement of FCBC Charger
Reference: JP16/FL39/3400005376/2391/2016-17 7/29/2016, Location: Asia
Category: Instruments
Scope of Work
The company invites bids for the supply, testing and Commissioning of FCBC Charger for SV-18. Since FCBC is required for Nickel Cadmium batteries, variation in voltage is not acceptable in any case. PLC Controlled FCBC is required for the site so that some critical alarms and some history log can also be generated. Constant Voltage in Charging (Float Boost) with constant voltage at load simultaneous required.
* The Specifications of Transducer are as follows:- - Auxiliary Supply: 20 to 70 VDC - Input Range: As per requirement Volt or mv (Span adjustable of voltage should be from 30 to 70 Volt) - Output Voltage: 4-20 rnA DC (Isolated 4-20 MA DC-DC Converter Modules) Isolated 4-20 rnA DC-DC Converter Module
* The Technical Details are as follows:- 1. Power supply voltage: 20 V to 70 V DC 2. Linearity and Accuracy: +- 0.5 % Over the entire range 3. Isolation between Input and Output: 2.2 KV 4. Type of Isolation: Optical and Galvanic 5. Load driving Capacity: Up to 600 Ohm 6. Protection for Input: Built in surge and over voltage protection 7. Protection for Output: Built in surge and over voltage protection : Fully Protected against Short Circuit and open Circuit 8. On site calibration facility panel control: Facility for adjustment of Zero and Span by means of front 9. Indication: Supply of indication of front panel 10. Operating Temperature: 0 to 55 Deg C 11. Enclosure: Compact Industrial Grade ABS enclosure : Dimensions: HXWXD= 100X55X120 mm (Maximum) 12. Mounting: 120mm (Maximum) Suitable for DIN rail mounting
The transducer shall have electrical isolation between Input and Output. The isolation insulation shall with stand 2 KV, 50 Hz for minimum one minute. The accuracy class of the transducer shall be 0.5. The transducer shall be protected against input and output voltage surge. The transducer shall be protected against input and output voltage surge. The transducer shall be suitable for driving up to 600 ohms load impedance located up to 500 meters away and wired with 0.5. mm2 copper conductor cables. The transducer shall be suitable for minimum 125 % continuous over load in input voltage/ Current parameter.
|
Related Prooducts: Instruments
Analyzers, Gas
Calibration Equipment
Calibrators, Electronic, Pneumatic
Concentration
Conductivity Meters
Density
Detector, Gas
Dissolved Oxygen meters
Drilling Instruments
Float Switch
Gas meters
General
Indicators and Recorders
Leak Locators
Level meters
Liquid Measurement
Load cells
Monitoring & Control
Mud Control
Mud Logging
pH and REDOX
Pressure gauges/ Transmitters
Radiation Detection
SCADA Systems
Temperature gauges/ Transmitters
Thermocouples
Thermowells
Transducers
Transmitters
Transmitters, Pressure
Turbidity Meters
Viscosity
Weather Station
Weighing Equipment
Related Tenders:
Analyzers, Gas
Calibration Equipment
Calibrators, Electronic, Pneumatic
Conductivity Meters
Density
Detector, Gas
Dissolved Oxygen meters
Drilling Instruments
Gas meters
General
Indicators and Recorders
Leak Locators
Level meters
Liquid Measurement
Monitoring & Control
Mud Logging
Pressure gauges/ Transmitters
SCADA Systems
Temperature gauges/ Transmitters
Thermocouples
Thermowells
Transmitters
Transmitters, Pressure
Viscosity
Weather Station
|
|
|
|