Gulf Oil and Gas
      Go to 3D Projects Premium Content Zone >>  |  Logon Oil and Gas

Portable Combustible (LEL) Gas, Hydrogen Sulphide
Reference: SDG9557P19/08 11/26/2018, Location: Asia
Category: Detector, Gas

Scope of Work
The company announces its need for supply of Portable Combustible (LEL) Gas, Hydrogen Sulphide.

Item Description:
Portable Combustible (LEL) Gas, Hydrogen Sulphide(H2S) Gas, Sulphur Dioxide(SO2) Gas Detector (Multigas) with digital indications and alarms and in-built suction pump for sampling.
1. Make: Bidder to specify
2. Model: Bidder to specify
3. Instrument must be Portable Hand-held.
4. Size & Weight: Weight should not be more than 450 gm including battery and suitable for one hand operation
5. Case Material: Should be rugged, impact resistant, noncorrosive composite material that will prevent spark generation.
6. Instrument Pump: Unit must have integrated pump with pump filters. The pump must be capable to take sample up to 25 feet, with line size 0.25 inch (6.35 mm) (approx.) in dia, should have a locking & quick release arrangement for sampling hoses & probes, should have pump filter window enabling users to visibly & nonintrusively check the pump filter, should have facility for replacement of pump filter with a single captive screw
7. Type of Sensors:
a) Electrochemical sensors & Plug-in type for H2S, SO2 gases.
(b) Catalytic Sensor & Plug-in type for Combustible gases.
8. Display of Gases: On a single screen of the gas detector, continuous monitoring for Hydrogen Sulphide (H2S), Sulphur Dioxide(SO2) Gas and Combustible Gases (LEL).
9. Measuring Specifications:
a) Hydrogen Sulphide: Range 0 - 100 ppm, Resolution 1 ppm.
b) Sulphur Dioxide(SO2): Range 0-100 ppm, Resolution 1 ppm.
c) Combustible Gases (LEL): 0 - 100% LEL, Resolution 1% LEL; 0 - 5% V/V, Resolution 0.1%.
d) Typical Response Time <= 30 Seconds.
e) Accuracy: +/- 2% measured value.
10. User Interfaces:
a) Display Type:Liquid Crystal (LCD) type display with
simultaneous readouts for each gas monitored in ppm, %LEL and %V/V values as applicable.
b) The system should equipped with backlight facility
c) Display Symbols (icons): Alarm icons will clearly advise alarm type like gas hazard and alarm level encountered, low battery condition and instrument status.
d) Keypad / Switches: One-button operation to activate the detector.
e) Instrument Alarm type: visual alarms, audible alarms,
vibrator alarms.
f) Number of alarm: Must be equipped with at least four (4) user selectable alarm levels for each gas sensed- High, Low,Time weighted average (TWA), Short term exposure limit(STEL)alarm for each type of gas measurement.
g) Over Limit Exposure Protection: For exposures above the instrument's measuring range for any sensor, the instrument will provide an over limit latching alarm that must be acknowledged.
h) Othr alarm: Low battery, instrument status, sensor status alarms.
i) Alarm Set Point: Adjustable over the measuring range
11. Instrument Power:
a) Lithium - ion / Lithium - Polymer Rechargeable Battery Pack.
b) Run Time >= 12 Hours in normal operation.
c) Charging Time =< 8 Hours.
12. Chargeable Option: 110 - 240 VAC, 50 Hz
13. Data Logging:
(a) Instrument should have all events & occurrences recoding facility.
(b) Should have inbuilt data storage facility.
(c) Data must be compatible for download.
14. Hazardous area: Intrinsically Safe (Ex ia) suitable for use in Class - I, Division - I, Groups - A, B, C, D/ Zone 1, Gas Group IIA, IIB, IIC, T3.
15. Operating Temperature: - 20 Deg. C to + 50 Deg. C.
16. Ingress Protection: IP 66/67.
17. Hands free operation: Suitable arrangement for hands free operation.
18. Calibration: Calibration must be fully automatic with Auto Zero & Auto Span functions, Self Check and Auto Diagnostics facilities. For calibration no other special tool will be required.
Instrument should show calibration due date
19. Humidity: 20 to 95% R.H. (non-condensing) continuous.
20. Sensors self life/ Warranty: minimum Two (02) years.
21. Accessories with each unit:
calibration cup/ adopter and calibration tubing(5 feet long) to enable calibration locally, Single unit battery charger, Rechargeable Battery, Installation Software/software for data download with Interface Data link Cable.



Related Prooducts: Detector, Gas Analyzers, Gas  Calibration Equipment  Calibrators, Electronic, Pneumatic  Concentration  Conductivity Meters  Density  Detector, Gas  Dissolved Oxygen meters  Drilling Instruments  Float Switch  Gas meters  General  Indicators and Recorders  Leak Locators  Level meters  Liquid Measurement  Load cells  Monitoring & Control  Mud Control  Mud Logging  pH and REDOX  Pressure gauges/ Transmitters  Radiation Detection  SCADA Systems  Temperature gauges/ Transmitters  Thermocouples  Thermowells  Transducers  Transmitters  Transmitters, Pressure  Turbidity Meters  Viscosity  Weather Station  Weighing Equipment 

Related Tenders: Analyzers, Gas  Calibration Equipment  Calibrators, Electronic, Pneumatic  Conductivity Meters  Density  Detector, Gas  Dissolved Oxygen meters  Drilling Instruments  Gas meters  General  Indicators and Recorders  Leak Locators  Level meters  Liquid Measurement  Monitoring & Control  Mud Logging  Pressure gauges/ Transmitters  SCADA Systems  Temperature gauges/ Transmitters  Thermocouples  Thermowells  Transmitters  Transmitters, Pressure  Viscosity  Weather Station 

Petro-Victory Energy Acquires 9 Onshore Assets in Brazil
Petro-Victory Appoints Gneiss Energy as Exclusive Financial Advisor
Petro-Victory Announces Acquisition of Remaining 50% Interest in São João Oil Field
Petro-Victory Receives Development Drilling Permits and Advances Drilling Program in Brazil
Exploration
Development
Oil & Gas Companies

Gulf Oil and Gas E-Marketplace - Premium Content

Copyright © Universal Solutions S.A.E. All rights reserved. Privacy Policy. - Contact Us