Scope of Work
The company announces its need for procurement of electrical cables (qty- 1000 m).

- Item 001: electric cables for bhel 'e-1400' diesel electric rig. Electric Cable for Drilling Rig.

Item Description: 2.5 sq. mm. 4 cores Ethylene Propylene Rubber (EPR) insulated CSP sheathed flexible copper, screened cable. Voltage Grade 660/1100 volts, suitable for temp. 85 °C. The outer CSP sheath should be heavy duty HOFR (Heat and Oil Resisting Flame Retardant) type.

Construction:
- Nominal Radial thickness of insulation: 1 mm.
- Nominal Radial thickness of sheath: 1.8 mm.
- No. of strands/Max diameters of each conductor strands: 50/0.26mm.
- Max. Resistance / KM of each core at 20 °C: 8.21 ohm/km.
a) Conductor should be bright tinned and annealed stranded copper conductor of high conductivity.
b) Cores should be identified by Red, Yellow, Blue and Black colour sequence.
c) An overall screened shall be provided over the laid up cores covered by a proofed cotton binding tape. Screened shall consist of 'May Pole' type braiding weave with high conductivity tinned annealed copper conductor.
d) All the outer interstices between laid up cores shall be filled with moisture proof textile materials or separate fillers made of sheathing materials.Applicable Standard:

- Item 002: electric cables for bhel 'e-1400' diesel electric rig ( with acscr system ) Electric Cable for Drilling Rig
Item Description: 2.5 sq. mm. 20 cores Ethylene Propylene Rubber (EPR) insulated CSP sheathed flexible copper, screened cable. Voltage Grade 660/1100 volts, suitable for temp. 85 °C. The outer CSP sheath should be heavy duty HOFR (Heat and Oil Resisting Flame Retardant) type.

Construction:
- Nominal Radial thickness of insulation: 1 mm.
- Nominal Radial thickness of sheath: 1.8 mm.
- No. of strands/Max diameters of each conductor strands: 50/0.26 mm.
- Max. Resistance / KM of each core at 20 °C: 8.21 ohm/km.
a) Conductor should be bright tinned and annealed stranded copper conductor of high conductivity.
b) All cores are to be marked by numbers printed in white,yellow (for colour of insulation - black) or in black (for colour of insulation - white), printed directly on insulated cores. The numbers should be clear and legible and repeated at an interval of 50mm. Core number to be printed in numerals as well as words.
c) An overall screened shall be provided over the laid up cores covered by a proofed cotton binding tape. Screened shall consist of 'May Pole' type braiding weave with high conductivity tinned annealed copper conductor.
d) All the outer interstices between laid up cores shall be filled with moisture proof textile materials or separate fillers made of sheathing materials. Applicable Standard:

- Item 003: Electric Cable for Drilling Rig Item.

Description: 1.5 sq. mm. 4 cores Ethylene Propylene Rubber (EPR) insulated CSP sheathed flexible copper, screened cable. Voltage Grade 660/1100 volts, suitable for temp. 85 °C. The outer CSP sheath should be heavy duty HOFR (Heat and Oil Resisting Flame Retardant) type.

Construction:
- Nominal Radial thickness of insulation: 1 mm.
- Nominal Radial thickness of sheath: 1.8 mm.
- No. of strands/Max diameters of strands: 30/0.26 mm.
- Max. Resistance / KM of each core at 20 °C: 13.70 ohm/km.
a) Conductor should be bright tinned and annealed stranded copper conductor of high conductivity.
b) Cores should be identified by Red, Yellow, Blue and Black colour sequence.
c) An overall screened shall be provided over the laid up cores covered by a proofed cotton binding tape. Screened shall consist of 'May Pole' type braiding weave with high conductivity tinned annealed copper conductor.
d) All the outer interstices between laid up cores shall be filled with moisture proof textile materials or separate fillers made of sheathing materials. Applicable Standard:

- Item 004: Electric Cable for Drilling Rig Item Description: 6 sq. mm.3.5 cores Ethylene Propylene Rubber (EPR) insulated CSP sheathed flexible copper, screened cable. Voltage Grade 660/1100 volts, suitable for temp. 85 °C. The outer CSP sheath should be heavy duty HOFR (Heat and Oil Resisting Flame Retardant) type.

Construction:
- Nominal Radial thickness of insulation: 1 mm.
- Nominal Radial thickness of sheath: 2 mm.
- No. of strands/Max diameters of each conductor strand: 120/0.31 mm for main core and 40/0.31 mm for half core. Max. Resistance / KM of each core at 20 °C: 3.39 ohm/km for main core and 5.09 ohm/km for half core.
a) Conductor should be bright tinned and annealed stranded copper conductor of high conductivity.
b) Cores should be identified by Red, Yellow, Blue and Black colour sequence.
c) An overall screened shall be provided over the laid up cores covered by a proofed cotton binding tape. Screened shall consist of 'May Pole' type braiding weave with high conductivity tinned annealed copper conductor.
d) All the outer interstices between laid up cores shall be filled with moisture proof textile materials or separate fillers made of sheathing materials.



Related Prooducts: Cables Accumulators and Storage batteries  Ammeters, Voltmeters, ect.  Batteries  Cable Trays  Cables  Cathodic Protection  Circuit Breakers  Contactors  Control Panels  Earthing materials  Electric fittings & junction box  Frequency Inverter  General  Lighting  Panel Components  Starter  Steel Panels  Switches  Transformers  Umbilical Lines  UPS 

Related Tenders: Accumulators and Storage batteries  Batteries  Cable Trays  Cables  Cathodic Protection  Circuit Breakers  Contactors  Control Panels  Earthing materials  Electric fittings & junction box  Frequency Inverter  General  Lighting  Panel Components  Starter  Switches  Transformers  Umbilical Lines  UPS 

Achany Extension Wind Farm Application Submitted
Pembina Pipeline Reports Results for the 2nd Quarter 2021 & Updates 2021 Guidance
Two Million VOLT Sparks Scottish Tidal Energy Scale up
Nigeria Approves NNPC’s $2.7B Stake Acquisition in Dangote Refinery
Exploration
Development
Oil & Gas Companies

Gulf Oil and Gas E-Marketplace - Premium Content

Copyright © Universal Solutions S.A.E. All rights reserved. Privacy Policy. - Contact Us